Appendix 3: Template Programming Tables
4 [401] Option 1 ON
Option 3 OFF
Option 4 ON
[406] 008
Double Call Enabled
Call Back Disabled
User Initiated Call Up Enabled
Number of Rings to Answer On is 8
After entering a valid 5-digit template programming code, the system prompts for the following data in the sequence listed:
1. Central Station Telephone Number
i. Program the required central station phone number. Press [#] to complete your entry.
ii. This phone number is entered into programming section [301][001].
2. Central Station System Account Code (4 or 6-digit code)
i. Program the system account code. Alldigits must be entered in order to complete your entry.
ii. This account code is entered into programming section [310][000].
3. Partition 1 Account Code (4 digit code)
i. Program the partition 1 account code. All digits must be entered in order to complete your entry.
ii. This account code is entered into programming section [310][001]
4. DLS Access Code (6-digit code)
i. Program the required DLS access code. All 6 digits must be entered in order to complete your entry.
ii. This access code is entered into programming section [403].
5. Entry Delay 1 and Exit Delay
i. Enter the 3-digit entry delay 1 (in seconds) followed by the desired 3-digit exit delay (in seconds). These entries affect
all partitions.
ii. All 3 digits must be entered in order to complete each section entry.
iii. These values are entered in programming sections [005][001]-[008] entry 1 and 3 respectively.
6. Installer's Code
i. Enter the 4 or 6-digit installer access code (dependent on section [041]). All digits must be entered in order to com-
plete the section entry.
ii. This code is entered into programming section [006][001].
iii. After the installer code has been programmed the system returns to the base installer programming menu.
iv. All template programming information defaults after performing a hardware or software panel default. The 5-digit tem-
plate programming code is defaulted to 00000.
Note: Pressing the pound key (#) advances through template programming, accepting what is displayed in these locations,
potentially overwriting desired programming. Depending on the option programmed, restoring the defaults using template
programming may not be possible.
- 207 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes