EasyManuals Logo

DSC Neo User Manual

DSC Neo
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #75 background imageLoading...
Page #75 background image
Section 5: Programming
146 TLM and Alarm
This output activates when a telephone line fault condition is present AND an alarm occurs. The output remains active until
an access code is entered to disarm or the TLM trouble is restored. The output activates for all audible and silent alarms
(except duress) if a TLM trouble is present. If an alarm activates this output in the disarmed state, it will deactivate when the
system is armed or the telephone line is restored. This output type also activates if alarms are in memory (not only for cur-
rently active alarms) when the TLM fault occurs. The alarms in memory must have exceeded the bell timeout.
147 Kissoff
This PGM output activates for two seconds after the alarm system receives a kissoff signal from the central station.
148 Ground Start
This output activates for two seconds before the alarm system attempts dialing to obtain a dial tone on Ground Start tele-
phone equipment. Two 2-second pauses must be inserted at the beginning of the telephone number when using this option.
149 Alternate Communicator
This output can be used to trigger inputs on a third-party communicator for the purpose of triggering alarm communications
to a monitoring station. This output can be programmed to activate when any of the following system events (alarms) occur
on the system:
l Fire (Fire Key, Fire Zones)
l Panic (Panic Key and Panic Zones)
l Burglary (Delay, Instant, Interior, Stay/Away and 24-hour Burglary Zones)
l Opening/Closing Events
l Zone Auto-Bypass. (Please see 08 Zone Auto-Bypass for details).
l Medical (Medical Key, Medical and Emergency Zones)
l Burglary Verified
l Opening After Alarm
l Emergency Alarm
l Duress Alarm
l Holdup Verified
In the armed state, this output deactivates when the system is disarmed. If an alarm activates this output in the disarmed
state, the output deactivates if a valid access code is entered within the bell timeout or if the system is armed after the bell
timeout has expired.
This output activates for silent and audible alarms or medical conditions only. It will not activate during pre-alert or delays.
Note: The PGM attributes for this option, programmed in section [010], differ from the standard selection of attributes nor-
mally programmed.
Note: When this PGM is configured to provide Opening/Closing status, the PGM must be programmed as a timed output, not
latching.
155 System Trouble
This output can be programmed to activate when any of the following trouble conditions are present:
l Service Required
l Loss of Clock
l DC Trouble
l Bus Voltage
l AC Trouble
l Device Fault
l Device Low Battery
l Device Tamper
l RF Delinquency
l Module Supervisory
l Module Tamper
l Communications
l Not Networked
This output deactivates when all of the selected trouble conditions are cleared.
- 75 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes

Related product manuals