3-10
Chapter 3 Advanced Operation
Irreg Set
01
P Length 297.0
Fold1 0.0
Fold2 0.0
7
Press the key.
Inputted numerical value is set, and [Fold1]
can be changed.
8
Input [Fold1] using the numerical
keypad.
Input [850].
Irreg Set
01
P Length 297.0
Fold1 85.0
Fold2 0.0
9
Press the key.
Inputted numerical value is set, and [Fold2]
can be changed.
10
Input [Fold2] using the numerical
keypad.
Input [950].
Irreg Set
01
P Length 297.0
Fold1 85.0
Fold2 95.0
11
Press the key.
The inputted numerical value is set, and the
display will return to the top screen.
The procedures taken after that will be the same as the
Chapter 2 “3. Standard Folding of Standard Paper”
(p.2-5)
The value of air volume of each fan, paper ejection conveyance amount, and stacker roller position that are
changed during special folding will be registered automatically.
When the registered numerical value has been ne-adjusted
• Press and hold the key to register the numerical value after ne-adjusting the registered value using
the stopper adjustment key. The buzzer sounds “pii” and the numerical value that has been ne-adjusted
is registered.
• When turning o the power without registering the value, the ne-adjusted numerical value will be
cleared.
• Air volume of each fan, paper ejection conveyance amount, and stacker roller position that are changed
during special folding will be registered automatically.
3-2. Using the registered data
Press the custom folding key to select the
registered data.