Endless zipper feed (optional)
206 Service Instructions 755 A/756 A - 00.0 - 02/2019
2. Turn the screw (3).
The distance between the upper side of the folder sole and the lower
edge of the guide plate is 8 mm.
3. Tighten the nut (4).
4. Loosen the nut (1).
5. Loosen the screw (2) until the lever (5) abuts on the screw (3) with
the pneumatic cylinder switched on.
6. Tighten the nut (1).
7. Open the menu Service > Multi test > Input/output test
to test the lifting movement of the guide plates with output
PWM2 ( p. 405).