Needle bar
30 Service Instructions 755 A/756 A - 00.0 - 02/2019
Setting the needle bar lengthwise
Fig. 17: Aligning the needle bar with the throat plate (3)
To set the needle bar lengthwise:
1. Remove the head cover.
2. Removing the arm cover
3. Slightly loosen the screw (1).
4. Turn the needles to bottom dead center.
(1) - Screw