Programming
Service Instructions 755 A/756 A - 00.0 - 02/2019 381
Cycle time
 The display switches to Cycle time.
Fig. 348: Cycle time
To test the cycle time:
1. Sew.
 The display shows the time in ms.
The cycle time allows you to optimize the machine settings.
2. To exit the test: access the menu Service > Machine test >
Machine workflow test again and press the button.