Troubleshooting
Service Instructions 755 A/756 A - 00.0 - 02/2019 453
1053 Mains voltage too high Check mains voltage
1054 Internal short circuit Replace control
1055 Sewing motor overload
Sewing motor blocked/not
moving freely
Sewing motor defective
Control defective
Eliminate seizing/stiff movement
Replace sewing motor
Replace control
1056 Sewing motor overtemperature
Sewing motor not moving freely
Sewing motor defective
Control defective
Eliminate seizing
1058 Sewing motor speed
Sewing motor defective Replace sewing motor
1060 Sewing motor excess current/
excess voltage
Encoder defective
Replace sewing motor cable
Replace encoder
Replace sewing motor
Replace control
1061 Encoder defective
Sewing motor excess current/
excess voltage
Replace sewing motor cable
Replace encoder
Replace sewing motor
Replace control
1120 Software error: Parameter not ini-
tialized
Perform software update
p. 431
•Check class
1203 Sewing motor: Position not
reached
Check mechanical changes to
the machine (e.g. thread cutting
setting, toothed belt tension)
Check position of thread lever at
top dead center
1302 Sewing motor current feed fault
Sewing motor blocked
Encoder cable not connected
or defective
Encoder defective
Remove blockage
Check encoder cable and replace,
if necessary
Replace sewing motor
1330 No answer from sewing motor Switch off and on the machine
again
Perform software update
p. 431
Replace control
1342-1344 Internal sewing motor error Switch off and on the machine
again
Perform software update
p. 431
Replace control
Error code Symbol Meaning Remedial action