Troubleshooting
458 Service Instructions 755 A/756 A - 00.0 - 02/2019
3030 Sewing motor: Phase error Test sewing motor phases
(R=2.8 OHM, high impedance
to PE)
Replace encoder
Replace sewing motor
Replace control
3040 Mains voltage drop Check mains voltage
3100 Control voltage:
Temporary mains voltage
interruption
Check mains voltage
3101 Power voltage:
Temporary mains voltage
interruption
Check mains voltage
3102 Voltage sewing motor:
Temporary mains voltage
interruption
Check mains voltage
3103 Voltage step motors:
Temporary mains voltage
interruption
Check mains voltage
3104 Pedal not in rest position
Setpoint device defective
Do not press the pedal when
starting up the machine
Replace setpoint device
3107 Machine temperature
Ventilation openings closed
Ventilation grille dirty
Check ventilation openings
Clean ventilation grille
3108 Speed limited due to insufficient
mains voltage
Check mains voltage
3109 Safety stop active Switch the Safe stop off
3121 Compressed air missing
Compressed air insufficient
Turn on compressed air
Stabilize compressed air
3123 Oil level too low Top off the oil p. 440
3210 Thread broken Insert thread
3220 Empty bobbin Change bobbin
3500 Error Command Interpreter
Motor synchronization Internal
error
Switch off and on the machine
again
Perform software update
p. 431
Feedback to Dürkopp Adler
Service
Error code Symbol Meaning Remedial action

Table of Contents