EasyManua.ls Logo

DURKOPP ADLER 867-M Premium - Disassembling and Assembling the Throat Plate

DURKOPP ADLER 867-M Premium
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Working basis
Service Instructions 867-M PREMIUM - 02.0 - 02/2017 21
3.4.6 Disassembling and assembling the throat plate
Fig. 10: Disassembling and assembling the throat plate
Disassembling the throat plate
To disassemble the throat plate:
1. Execute the service routine Feed Dog > Pos To Needle
( p. 14).
The software is used to define the necessary presettings on the
machine.
2. Open the throat plate slide ( p. 20)
3. Loosen the screws (1).
4. Remove the throat plate (2).
5. Finish the service routine.
Assembling the throat plate
To assemble the throat plate:
1. Execute the service routine Feed Dog > Pos To Needle
( p. 14).
The software is used to define the necessary presettings on the
machine.
2. Insert the throat plate (2).
Ensure that the nose (4) of the bobbin case (3) is in the cutout of the
throat plate (2).
3. Tighten the screws (1).
4. Close the throat plate slide ( p. 20).
5. Finish the service routine.
(1) - Screws
(2) - Throat plate
(3) - Bobbin case
(4) - Nose