2 Installation
2.1 RJ 45 interface
CANopen for DA1, DC1, DE11 09/16 MN040019EN www.eaton.com 11
2 Installation
2.1 RJ 45 interface
This chapter explains how to connect DA1, DC1, and DE11 variable
frequency drives to a CANopen network.
The CANopen interface is integrated into the RJ45 interface.
Figure 2: RJ 45 interface
The RJ45 interface‘s location will depend on the specific device model and
the variable frequency drive‘s frame size.
→
For more detailed information on where the RJ45 interface is
located, please refer to the instruction leaflet corresponding to
the relevant variable frequency drive.
CAN_L 1
CAN_H 2
0 V 3
OP-Bus_L 4
OP-Bus_H 5
+24 V 6
Modbus RTU_L 7
Modbus RTU_H 8
DC1
DE1
DA1
L1/L
L2/N
L3
DC-
U
DC+
BR
1 2 3 4 5 6 7 8 9 10 11 12 13
14 15 16 17 18
COM
V
W
L1/L
L2/N
L3
U
V
W
0 V +10 V 1 2 3 4 13 14
L1/L
L2/N
L3
U
V
W
1
2
3
4
5
6
7
8
9
10
11