EasyManua.ls Logo

EC-PACK EC-JET 1000Pro - Print Head Temperature; Deflector Voltage

EC-PACK EC-JET 1000Pro
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Guangzhou EC-PACK Packaging Equipment Co., Ltd.
EC-JET 1000Pro Continuous Inkjet Printer
79
The user should normally select to reset the printer.
Following a print failure shutdown, the software sets:
Pressure to zero
EHT off
All valves closed
300V off these settings cannot be altered until the print failure has been cleared (i.e. the jet cannot be
restarted).
The following pages give a brief description of each Print Failure and what should be done to correct it. In
each case, if the suggested action does not rectify the error condition, you should contact your local
distributor.
9.3.2 2.00 Print head Temperature
The print head temperature sensor indicates that a temperature around or in the print head has exceeded
the safe operating limit. This may mean that a fire has occurred within the head cover.
Possible causes
● Excessive local heat source:
Relocate the print head away from the heat source.
● Fire in the print head:
Have your printer checked by your local engineer.
9.3.3 2.01 Deflector Voltage
The voltage on the deflector plates has discharged which is normally caused by ink build-up.
Possible causes
● Excess build-up of ink on deflector plates:
Clean the print head as described earlier in this manual (see “Routine Maintenance”).
Static discharge:
Check for any source of excess static electricity.