7.1.2 Chemical connection
Personnel:
n
Manufacturer
n
Operator
n
Specialist
n
Production supervisor
DANGER!
Personal protective equipment, or PPEis used to protect personnel. The
PPE described on the product data sheet for the dosing medium must be used.
1. Using hose (12/21 PVC fabric) connect the suction lance to the applicator station.
2. Fasten the return hose (12/21 PVC fabric) to the return connection of the diaphragm
valve with hose clip.
3. Lay the return hose along the suction hose up to the suction lance and secure using
cable ties.
ð
The end of the hose should be positioned at roughly half the height of
the suction lance.
4. Place the suction lance with return hose into the product container.
5. Connect the empty detector unit plug from the suction lance to the control unit.
WARNING!
Ensure that here are no blockages in the return hose and ensure that the hose
is not kinked and that it is routed back to the hopper reservoir with a free
downwards gradient!
Connection
DryExx connection overview® > Chemical connection
41 Rev. 02-09.2017