12 Troubleshooting
CAUTION!
The remedying of defects in circuits that are live, or under pressure, should
only be carried out by specialist qualified personnel.
Fault description Cause Remedy
Dosing pump is not drawing in. See pump manual. See pump manual.
Reduced dosing output. Air control line is
providing too little
pressure.
Check filter pressure regulator
and 3/2 way solenoid valve.
Check compressed air circuits
No pressure build-up in the
product line.
Check circuit pipes. Eliminate leaks.
Increase operating air pressure.
Check pressure release
valve.
Clean or replace valve.
12.1
Troubleshooting for Lub-O-DryExx
®
Diaphragm compressed air pump
Lub-O-DryExx
®
Article No. 182830
ALMATEC compressed air diaphragm pump, type CUBUS 15
Fault description Cause Remedy
Pump is not running Supply line blocked/closed Open air supply
Muffler blocked clean or replace
Pressure line blocked/closed clean, open valve
Operating chambers blocked Remove contamination
Air control faulty Replace air control
Pump is running irregularly Piston rings worn Replace piston rings
Air control worn Replace air control
Diaphragm broken Replace diaphragms, clean
pump
Air control dirty Clean/replace control
Valve ball/body blocked clean, remove foreign
bodies.
Ice formation Improve air treatment
Air in the conveyed medium Suction line leaky Seal suction line
Container with conveyed medium
empty
fill/new container
Diaphragm broken Replace diaphragms
Exhaust line (cavitation) Adjust intake height, fit
intake air vessel if
necessary
Troubleshooting
Troubleshooting for Lub-O-DryExx® Diaphragm compressed air pump
81 Rev. 02-09.2017