EasyManua.ls Logo

Eldes EPIR3 - Page 52

Eldes EPIR3
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
52
52 EN
EPIR3 User Manual v1.3
Detector Sensitivity Level Settings
Function Command Value Range / Comment Example
Change the
sensitivity level of
the detector
XXXX_LEVEL:YY YY = [20... 99]
The greater the value, the lower the sensitivity
level of the detector.
The EPIR3 device is pre-set by the manufac-
turer at the optimal detector sensitivity level.
However, in some cases, for instance where the
system is installed in windy premises, the air
ow can cause false alarms. In this case you can
reduce the sensitivity level.
1111_LEVEL:35
Check the sensi-
tivity level of the
detector
XXXX_LEVEL 1111_LEVEL
Wireless Device Management
Function Command Value Range / Comment Example
Disable wireless
module
XXXX_RF:OFF The system disables the built-in wireless
module
1111_RF:OFF
Enable wireless
module
XXXX_RF:ON 1111_RF:ON
Pair a wireless
device to the
system
XXXX_SET:YYYYYYYY YYYYYYYY = 8-character wireless device
ID code
1111_
SET:5261841A
Remove a wire-
less device from
the system
XXXX_DEL:YYYYYYYY YYYYYYYY = 8-character wireless device
ID code
1111_
DEL:5261841A
Replace a wireless
device by another
wireless device of
the same model
1111_REP:YYYYYY
<ZZZZZZZZ
YYYYYYYY = old 8-character wireless
device ID code; ZZZZZZZZ = new 8-char-
acter wireless device ID code
1111_
REP:5261841A
<41286652
Verify free wire-
less channels
XXXX_STATUS_FREE The system will send you a text by return,
with the number of available free wire-
less channels.
1111_STATUS_FREE
NOTE: The underscore symbol ‘_’ in these instructions represents a space. So when typing an SMS text
message, replace the underscore symbol with a single space.