EasyManua.ls Logo

Electrolux T4130 - Temperature Settings; Inlet Temperature Configuration; Hysteresis and Autostop Settings

Electrolux T4130
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
33
6204
36
6204
35
CONFIG 2
MENU 5-2
TEMPERATURE
ROTATION
MAXIMUM
RESET COUNTERS
ELS NETWORK
TEMPERATURE
Select the row TEMPERATURE and press the
knob.
The display shows the accessible functions/
parameters regarding the temperature - the default
values are listed to the right:
• INLET TEMPERATURE N/A *
HYSTERESIS 2 °C
AUTOSTOP N/A *
(For a more detailed description of the functions/
parameters see below.)
* There are no default values listed as the values
depend on the con guration of the machine.
To adjust parameter values set the value and
press the knob.
Fig.
36
Fig.
35
TEMPERATURE
MENU 5-2-1
INLET TEMPERATURE
HYSTERESIS
AUTOSTOP
EXIT
Program unit
INLET TEMPERATURE
Select the inlet temperature, 80-180°C. However, all machines without inlet sensor = 0°C eg.
T4130.
HYSTERESIS
Select the hysteresis on the outlet temperature, 1-10°C.
AUTOSTOP
Select the outlet temperature the dryer must reach before it stops and the clothes are dry,
30-70°C - only on dryers with this function.

Table of Contents

Other manuals for Electrolux T4130