EasyManua.ls Logo

Electrolux T4130 - Maximum Setting Limits; Program Count and Time Limits; Pendling Time Configuration

Electrolux T4130
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35
6204
40
6204
39
CONFIG 2
MENU 5-4
MAXIMUM
RESET COUNTERS
ELS NETWORK
CONFIG 3
EXIT
MAXIMUM
Select the row MAXIMUM and press the knob.
The display shows the accessible parameters
regarding the maximum settings - the default
values are listed to the right:
NUMBER OF PROGRAMS 0 - 9 *
TIME ON TIME P 90
TIME ON AUTOMATIC P 90
PENDLING TIME 20 - 255 *
(For a more detailed description of the parameters
see below.)
To adjust parameter values set the value and
press the knob.
* The default value is depending on the machine
type
Fig.
40
Fig.
39
MAXIMUM
MENU 5-4-1
NUMBER OF PROGRAMS
TIME ON TIME P
TIME ON AUTOMATIC P
PENDLING TIME
EXIT
NUMBER OF PROGRAMS
Select the number of programs in the dryer
0 = coin
2 = AHL Autostop
3 = AHL RMC
5 = OPL Autostop
9 = OPL RMC
TIME ON TIME P
Select the maximum time for time programs: 10 - 90 minutes
TIME ON AUTOMATIC P
Select the maximum time for automatic programs: 10 - 90 minutes
PENDLING TIME
Select the earliest time the dryer can start after it has been stopped: 20-255 seconds.
120 = Electric heated, steam heated
20 = Gas heated, Electric heated T4250/4350, T4300, T4190
Program unit

Table of Contents

Other manuals for Electrolux T4130

Related product manuals