42
Error codes overview
Error Description
code
E 01 Option Not in use.
E 02 Option Not in use.
E 03 Inlet air - Sensor has short-circuited The thermistor element measuring the air
inlet temperature to the drum, or the wiring to the sensor has shorted.
E 04 Outlet air - Sensor has short-circuited The thermistor element measuring the air
outlet temperature from the drum, or the wiring to the sensor has shorted.
E 05 Fan motor Motor 1: The thermal protection switch in the motor, or its harness, is
open.
E 06 Drum motor – Motor 2: The thermal protection switch in the motor, or its harness, is
open.
E 07 Option Not in use.
E 08 Inlet and Outlet air protection thermostats One of the proctection thermostats has
opened due to overheating.
E 09 Option Not in use.
E 10 Setting Programming error / incorrect or missing parameter(s).
E 11 Drying error Maximum allowable RMC time exceeded (non-coin operated models
only).
E 12 Drying error Maximum allowable Autostop time exceeded (non-coin operated
models only).
E 13 Drying error - Requested drying time is longer than maximum allowed.(dryer
connected to a payment system).
E 14 Gas error - A flame was not detected on gas heated dryers.
E 15 Vacuum switch The vacuum switch/pressostat does not shut within 12 seconds after
the dryer is started.
E 16 Vacuum switch The vacuum switch/pressostat was already closed when an attempt
to start the dryer was made.
E 17 Inlet sensor disconnected The inlet thermistor or wiring to the thermistor is open.
E 18 Outlet sensor disconnected The outlet thermistor or wiring to the thermistor is
open.
E 19 Option Not in use.
E 20 CMIS out of operation The dryer is put out of order in the PC programme.
E 21 CMIS com board poll error The PC does not poll the dryer within the time out.
E 22 LM10 com board poll error The PC does not poll the dryer within the time out.
E 23 Option Not in use.
E 24 Condensate container The condensate container is full and the pump is not pumping.
Troubleshooting