E 15 - Air pressure switch or vacuum switch
Error description
The air pressure switch or the vacuum switch does not shut within 12 seconds after the
fan has started.
Error analysis
Check the motor’s
connection and phase
order.
NO
YES
Go to step 3.
2. Does the fan motor
rotate in the correct
direction?
Resetting
Resetting is done by opening/closing the dryer loading door and pressing the start button
NO
YES
YES
Replace PCB
3. Is the measuring
over 100V AC
between P2-5 and
P2-2 within 12
seconds when dryer
is not operating.
NO
See check list.
Correct airflow problem
as appropriate.
1 Is the
underpressure in the
drum compartment
below 90Pa.
Go to step 2.
Replace the air pressure
switch.