60
E 18 - Output sensor disconnected
Error description
This error is displayed when the outlet NTC sensor is disconnected.
Error analysis
Measure the resistance on
the NTC sensor between
P18-5 and P18-6 on PCB.
Is the resistance between
4kΩ and 6kΩ at 20°C
(68°F)?
Replace NTC sensor
or harness.
Go to step 2.
NO
YES
1. Defective NTC
sensor/harness?
Resetting
Resetting is done by opening/closing the dryer loading door and pressing the start button
Alternative
Measure voltage between GND and T1
0
10
20
30
40
50
60
70
80
90
100
0
C
12345T1 (V)
T2 T1 GND
Troubleshooting