Description of the Operating Displays
BA_Elmasteam_8_Vers.07.2016 © Elma Schmidbauer GmbH
illuminates as
blue
Warning (A)
flashes red
Warning Tone
sounds
continuously in
operation
soft/strong
Filling level low, below the
minimum
Switch off the warning tone,
select the function steam
outlet or
lock in the
programme selection
Device with/without pump:
Fill the device manually
- Fill the device to filling
level minimum, the
display warning (A) goes
out
- Fill the device to filling
level maximum, the
display warning (B) goes
out
flashes blue
Warning (A)
flashes red
(Device with
pump)
With automatic filling, the
filling process will not be
started (safety shut-down of
the pump)
Fill the device manually to
filling level minimum (2
litres)
Inspect the ventilation hose
on the canister and, where
necessary, connect it.
Device with fixed-water
supply:
Inspect the hose connection
Switch off the device: Let it
cool down
Switch on the device:
automatic filling
(depressurised devices start
with the filling process
again)
B A