6.3.25 Set sleep mode time
Set the time before the product enters sleep mode when no user interaction has been taken place in the
LCD menu. The user needs to enter the 4 digit password in the LCD menu to be able to continue
configuration of the product.
6.3.25.1 Master to slave
0x43 | 0x53 | 0x63 | 0x73
A-Field = Address of slave
CI-Field = Master to slave data send
0x017C03656C73nn
OR
0x01FC036E616Cnn
Write sleep mode time
nn = 8 bit unsigned sleep mode in minutes.
Valid range: 0..255
6.3.26 Set LCD menu password
Set the LCD menu password which needs to be entered to access the LCD menu. The default password is
0000.
6.3.26.1 Master to slave
0x43 | 0x53 | 0x63 | 0x73
A-Field = Address of slave
CI-Field = Master to slave data send