Elvaco CMeX50 - Factory Defaults

Elvaco CMeX50
89 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CMeX50 Users Manual English
CMeX50 Users Manual English
Interfaces
IR, Integrated
M-Bus Master,
Wireless M-Bus
Receiver, M-
Bus slave
-
Maximum number of M-Bus
devices (software limit)
M-Bus Master:
32 meters,
Wireless M-Bus
Receivers: 800
meters
-
Decryption
Yes
-
Integrated M-Bus Master
M-Bus standard
EN 13757
-
M-Bus baud rate
300 and 2400
bit/s
Nominal voltage
28
VDC
Maximum unit loads
32/48
T/mA
Can be extended with the CMeX10-
13S Series
M-Bus search modes
Primary,
secondary
-
Maximum cable length
1000
M
100 nF/km, maximum 90 Ω
Wireless M-Bus Receiver
M-Bus standard
EN 13757-4
-
Wireless M-Bus modes
S1, T1, C1
-
Maximum number of M-Bus
devices
800
-
Radio frequency band
868
MHz
Encryption
AES-128
-
RF sensitivity
-105
dBm
OMS compliant
Yes
-
M-Bus slave interface
M-Bus standard
EN 13757
-
M-Bus baud rate
300 and 2400
bit/s
Nominal voltage
21-42
VDC
Power consumption
1.5/1
mA/T
M-Bus search modes
Primary,
secondary,
enhanced
secondary
-
M-Bus default address
251
-
Table 13 Technical specifications