5.12 HART
®
multi-drop configuration
The Rosemount 5300 Series Transmitter can be run in multidrop mode. In the multidrop
mode each transmitter has a unique HART address.
Figure 5-9: Multidrop Connection
5.12.1 Change the poll address using Rosemount Radar Master
To set the desired address for multidrop operation:
Procedure
1. Select Setup → General.
2. Select the Communication tab.
3. Set the desired address for multidrop operation.
• HART 5: addresses between 1 and 15
• HART 7: addresses between 1 and 63
4. Click the Store button to save the new address.
Configuration Reference Manual
April 2019 00809-0100-4530
156 Rosemount 5300 Level Transmitter