EasyManua.ls Logo

Emerson Rosemount 5300 Series - Supported Units

Emerson Rosemount 5300 Series
488 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table F-7: LCD Parameters (continued)
Bit Number Value of LCD_PARAMETERS Description
17 0x00020000 Surface Noise Margin
18 0x00040000 Vapor DC
Table F-8: Product Dielectrical Range
VALUE ENV_DIELECTR_CONST
0 1.4 - 1.9 (e.g. liquified gas, plastics)
1 1.9-2.5 (e.g. Oil Based)
2 2.5-4 (e.g. Oil Based)
3 4-10 (e.g. Alcohol, Acids)
4 >10 (e.g. Waterbased)
5 Unknown
Table F-9: Measurement Mode
VALUE MEAS_MODE
0 Liquid Product Level
1 Product Level and Interface Level
2 Solid Product Level
3 Interface Level with Submerged Probe
F.3 Supported units
Unit codes
Table F-10: Length Units
ID Display Description
1010 m meter
1012 cm centimeter
1013 mm millimeter
1018 ft feet
1019 in inch
Reference Manual Level Transducer Block
00809-0100-4530 April 2019
Reference Manual 433

Table of Contents

Other manuals for Emerson Rosemount 5300 Series