The transmitter can easily be configured using a handheld communicator or a PC with the
Rosemount Radar Master software. Rosemount 5300 Level Transmitters can also be
configured with the AMS Suite and DeltaV
software, and other tools supporting
Electronic Device Description Language (EDDL) functionality.
Figure 2-4: HART System Architecture
$
%
&
'
(
)
*
+
,
-
A. Integral display
B. Rosemount 5300 Level Transmitter
C. 4-20 mA/HART
D. Rosemount 751 Field Signal Indicator
E. Handheld communicator
F. 3 x 4-20 mA
G. Rosemount 333 HART Tri-Loop
H. HART modem
I. Rosemount Radar Master or AMS Suite
J. DCS
Note
For HART communication, a minimum load resistance of 250 Ohm within the loop is
required.