Table A-13: Process Connection with Plate Design
Standard Bolting material Gasket Flange material Hub material
Standard/HP/
HTHP/C
HP/HTHP/C
ASME Stainless steel
SA193 B8M Cl.2
Soft (1a) with min.
thickness 1.6 mm
Spiral wound
gasket with
nonmetallic filler
(1b)
Stainless steel
A182 Gr. F316L/
F316 and EN
10222-5-1.4404
SB574 Gr. N10276
or SB164 Gr.
N04400
EN, JIS EN 1515-1/-2
group 13E0,
A4-70
Soft (EN 1514-1)
with min.
thickness 1.6 mm
Spiral wound
gasket with
nonmetallic filler
(EN 1514-2)
Table A-14: Alloy C-276 Flanges
Standard Bolting material Gasket Flange material Hub material
Standard/HP/
HTHP
HP/HTHP
ASME UNS N10276 Soft (1a) with min.
thickness 1.6 mm
Spiral wound
gasket with
nonmetallic filler
(1b)
SB462 Gr. N10276
(solution
annealed
condition) or
SB575 Gr. N10276
(solution
annealed
condition)
SB574 Gr. N10276
EN Soft (EN 1514-1)
with min.
thickness 1.6 mm
Spiral wound
gasket with
nonmetallic filler
(EN 1514-2)
Table A-15: Duplex 2205 Flanges
Standard Bolting material Gasket Flange material Hub material
Standard/HTHP HP/HTHP
ASME A193 B7 or A320
L7
Soft (1a) with min.
thickness 1.6 mm
Spiral wound
gasket with
nonmetallic filler
(1b)
Duplex stainless
steel SA/A182 F51
and
EN10222-5-1.446
2 or SA/A240 Gr.
S31803 and
EN10028-7-1.446
2
Stainless steel
SA479M S31803
and EN
10272-1.4462
EN Bumax
®
88 Soft (EN 1514-1)
with min.
thickness 1.6 mm
Spiral wound
gasket with
nonmetallic filler
(EN 1514-2)
A.2.14 Interface measurements
The Rosemount 5302 is a good choice for measuring the interface of oil and water, or
other liquids with significant dielectric differences.
It is also possible to measure interface with a Rosemount 5301 in applications where the
probe is fully submerged in the liquid, using the submerged probe mode.
Specifications and reference data Reference Manual
April 2019 00809-0100-4530
296 Rosemount 5300 Level Transmitter