Special Conditions for Safe Use (X):
1. WARNING – Potential Electrostatic Charging Hazard – The enclosure contains non-
metallic material. To prevent the risk for electrostatic sparking the plastic surface
should only be cleaned with a damp cloth.
2. WARNING – The apparatus enclosure contains aluminum and is considered to
constitute a potential risk of ignition by impact or friction. Care must be taken into
account during installation and use to prevent impact or friction.
B.5.2 I5 Intrinsic Safety (IS), Nonincendive (NI)
Certificate
FM16US0444X
Standards
FM Class 3600 – 2018; FM Class 3610 – 2010; FM Class 3611 – 2004; FM
Class 3615 – 2006; FM Class 3810 – 2005; ANSI/ISA 60079-0 – 2013;
ANSI/ISA 60079-11 – 2012; ANSI/NEMA 250 – 2003;
Markings
IS CL I, II, III, DIV 1, GP A, B, C, D, E, F, G in accordance with control drawing
9240030-936; IS (Entity) CL I, Zone 0, AEx ia IIC T4 in accordance with
control drawing 9240030-936, NI CL I, II, III DIV 2, GP A, B, C, D, F, G; T4; -50
°C ≤ Ta ≤ 60 °C / 70 °C; Type 4X
Special Conditions for Safe Use (X):
1. WARNING –Potential Electrostatic Charging Hazard – The enclosure contains non-
metallic material. To prevent the risk for electrostatic sparking the plastic surface
should only be cleaned with a damp cloth.
2. WARNING – The apparatus enclosure contains aluminum and is considered to
constitute a potential risk of ignition by impact or friction. Care must be taken into
account during installation and use to prevent impact or friction.
Ui Ii Pi Ci Li
Entity parameters HART 30 V 130 mA 1 W 7.26 nF 0
Entity parameters
Fieldbus
30 V 300 mA 1.3 W 0 0
B.5.3 IE FISCO
Certificate
FM16US0444X
Standards
FM Class 3600 – 2018; FM Class 3610 – 2010; FM Class 3611 – 2004; FM
Class 3615 – 2006; FM Class 3810 – 2005; ANSI/ISA 60079-0 – 2013;
ANSI/ISA 60079-11 – 2012; ANSI/NEMA 250 – 2003;
Markings
IS CL I, II, III, DIV 1, GP A, B, C, D, E, F, G; T4; in accordance with control
drawing 9240030-936; IS CL I, Zone 0 AEx ia IIC T4 in accordance with
control drawing 9240030-936; -50 °C ≤ Ta ≤ 60 °C / 70 °C; Type 4X
Product certifications Reference Manual
April 2019 00809-0100-4530
360 Rosemount 5300 Level Transmitter

Table of Contents