3.4.3 Mount a centering disc on rigid single lead probe (13
mm)
Procedure
1. Drill two holes using the drilling fixture (included in your shipment).
2. Mount the bushings and centering disc at the probe end.
3. Adjust distance by shifting hole for split pin in lower bushing.
0.16 in. (4 mm)
0.08 in. (2 mm)
4. Insert the split pins through the bushings and the probe.
Mechanical installation Reference Manual
April 2019 00809-0100-4530
66 Rosemount 5300 Level Transmitter