The length of the loop will add to the Blind Zone. The location of the chuck will determine
the beginning of the Blind Zone.
The Probe Length should be configured as the distance from the Upper Reference Point to
the top of the chuck.
Figure 3-28: Flexible Single Lead Probe with Chuck
A ring (customer supplied) can be attached to the weight in a threaded (M8x14) hole at
the end of the weight. Attach the ring to a suitable anchoring point.
Figure 3-29: Flexible Twin/Single Lead Probe with Weight and Ring
A. Weight with internal threads M8x14
B. Ring
A magnet (customer supplied) can be fastened in a threaded (M8x14) hole at the end of
the weight. The probe can then be guided by placing a suitable metal plate beneath the
magnet.
Reference Manual Mechanical installation
00809-0100-4530 April 2019
Reference Manual 89