209
Reference Manual
00809-0100-4026, Rev HA
Appendix A: Reference data
November 2014
Reference Data
GC Transparent meter glass protection cover made of PTFE / FEP
T1 Transient protection terminal block (standard with FISCO options)
Factory configuration
C1 Factory configuration (Configuration Data Sheet required with order, available at www.rosemount.com)
Alarm limit configuration
C4 NAMUR alarm and saturation levels, high alarm
C8
(9)
Low alarm (standard Rosemount alarm and saturation levels)
Overfill
U1
(10)
WHG Overfill approval
Special certifications
Q4 Calibration Data Certificate
Q8
(11)
Material Traceability Certification per EN 10204 3.1
N2
(12)
Certificate of compliance with guidelines in NACE MR0175/ISO 15156 and NACE MR0103
QG GOST Primary Verification Certificate
Safety certifications
QS
(10)
Prior use certificate of FMEDA data
Shipboard approvals
(13)
SBS American Bureau of Shipping Type Approval (consult factory for details)
SDN Det Norske Veritas (DNV) Type Approval (consult factory for details)
SLL Lloyd's Register Type Approval (consult factory for details)
SBV Bureau Veritas Type Approval (consult factory for details)
SRS Russian Maritime Register of Shipping Type Approval (consult factory for details)
SGL Germanischer Lloyd Type Approval (consult factory for details)
Special procedures
P1
(8)
Hydrostatic testing
Antenna extension
S3
(14)
Cone Antenna extension in 316 / 316L / EN 1.4404 SST. To be used if there are irregularities in the nozzle.
Fits nozzles up to 20 in. (500 mm).
Diagnostics functionality (see page 186 for more information)
D01 FOUNDATION fieldbus Diagnostics Suite (includes Signal Quality Metrics diagnostics)
(consult factory for details)
DA1 HART Diagnostics Suite (includes Signal Quality Metrics diagnostics) (consult factory for details)
Table A-10. 5402 High Frequency Radar Level Transmitter Ordering Information
The starred options () represent the most common options and should be selected for best delivery. The non-starred offerings