226
Reference Manual
00809-0100-4026, Rev HA
Appendix B: Product certifications
November 2014
Product Certifications
B.5.6 Brazilian certifications
NCC/INMETRO Approvals
Special Condition for Safe Use (X):
Refer to Certificate NCC 14.2256X
Standards
ABNT NBR IEC 60079-0:2013, ABNT NBR IEC 60079-1:2009, ABNT NBR IEC 60079-11:2009;
ABNT NBR IEC 60079-26:2008, ABNT NBR IEC 60079-27:2010, ABNT NBR IEC 60079-31:2011
E2 Flameproof:
Ex ia/db ia IIC T4 Ga/Gb(-40 °C
dTa d+70 °C
(1)
)
Ex ta IIIC T79 °C
(2)
IP66/67
I2, IB Intrinsically safe:
Ex ia IIC T4 Ga/Gb (-50 °C
dTa d+70 °C
(1)
)
Ex ta IIIC T79 °C
(2)
(-50 °C dTa d+70 °C
(1)
)
IP66/67
4-20mA / HART model: U
i
=30 Vdc, I
i
=130 mA, P
i
=1.0 W, C
i
=7.26 nF, L
i
=0 H.
F
OUNDATION™ fieldbus model: U
i
=30 Vdc, I
i
=300 mA, P
i
=1.5 W, C
i
=4.95 nF, L
i
=0 H.
FISCO model: U
i
=17.5 Vdc, I
i
=380 mA, P
i
=5.32 W, C
i
=4.95 nF, L
i
<1 ì H.
B.5.7 Chinese certifications
National Supervision and Inspection Center for Explosion
Protection and Safety of Instrumentation (NEPSI) approvals
Special Condition for Safe Use (X):
Refer to Certificate GYJ111229X
E3 Flameproof:
Ex d ia IIC T4 (-40 °C < Ta < +70 °C
(1)
)
U
m
=250 V
I3 Intrinsically safe:
Ex ia IIC T4 (-50 °C < Ta < +70 °C
(1)
)
DIP A20 Ta 79°C
(2)
(-50 °C < Ta < +70 °C
(1)
)
4-20 mA / HART model: U
i
=30 Vdc, I
i
=130 mA, P
i
=1.0 W, C
i
=7.26 nF, L
i
=0 H.
F
OUNDATION fieldbus model: U
i
=30 Vdc, I
i
=300 mA, P
i
=1.5 W, C
i
=4.95 nF, L
i
=0 H.
FISCO model: U
i
=17.5 Vdc, I
i
=380 mA, P
i
=5.32 W, C
i
=4.95 nF, L
i
<1 ì H.
(1) +60 °C with FOUNDATION fieldbus option or FISCO option.
(2) +69 °C with F
OUNDATION fieldbus option or FISCO option.