262
Reference Manual
00809-0100-4026, Rev HA
Appendix E: Level transducer block
November 2014
Level Transducer Block
Table E-6. Presentation
Table E-7. LCD Parameters
Bit Number
Value of
ENV_PRESENTATION
DESCRIPTION
0 0x00000001 Reserved
1 0x00000002 Level above min distance possible
2 0x00000004 Predicting_Allowed
3 0x00000008 Bottom echo always visible if tank is empty
4 0x00000010 Tank contains double bounces
5 0x00000020 Slow Search
6 0x00000040 Enable double surface
7 0x00000080 Select lower surface
8 0x00000100 Bit 7, Reserved
9 0x00000200 Show negative level as zero
10 0x00000400 Bit 9, Reserved
11 0x00000800 Bottom Projection
12 0x00001000 Bit 11, Reserved
13 0x00002000 Don't set invalid level in antenna zone
14 0x00004000 Don't set invalid level when full
15 0x00008000 Don't set invalid level when full
16 0x00010000 Bit 15, Reserved
17 0x00020000 Bit 16, Reserved
18 0x00040000 Bit 17, Reserved
19 0x00080000 Use jump filter
20 0x00100000 Bit 19, Reserved
21 0x00200000 Use Extra echo detection
22 0x00400000 Always track first echo
23 0x00800000 Bit 22, Reserved
24 0x01000000 Bit 23, Reserved
25 0x02000000 Calculate signal quality metrics
26 0x04000000 Infinite alarm delay
27 0x08000000 Bit 26, Reserved
28 0x10000000 Bit 27, Reserved
29 0x20000000 Bit 28, Reserved
30 0x40000000 Bit 29, Reserved
31 0x80000000 Bit 30, Reserved
Bit Number
Value of
ENV_PRESENTATION
DESCRIPTION
0 0x00000001 Reserved
1 0x00000002 Level
2 0x00000004 Distance
3 0x00000008 Level Rate
4 0x000000010 Signal Strength
5 0x000000020 Volume
6 0x000000040 Internal Temperature
7 0x000000080 Bit 6, reserved
8 0x000000100 Bit 7, reserved

Table of Contents