Reference Manual
00809-0100-4731, Rev FA
April 2003
APEX
™
and APEX Sentry
™
Radar Gauge
3-16
Figure 3-9. HART Communicator Menu Tree for the APEX and APEX Sentry Radar Gauges
NOTE
The Review Menus list all of
the information stored in the
radar gauge. This includes
device information,
measuring element, signal
condition, output condition, and
software revision.
1.STATUS
2.Master Reset
1.Distributor
2.Model
3.Dev id
4. Tag
5.Date
6.Write Protect
7.Descriptor
8.Message
9.REVISIONS
- CONSTRUCTION MATLS
1.DEVICE SETUP
2. PV
3. AO
4.LRV
5.URV
1.PROCESS
VARIABLE
2.DIAGNOSTICS
AND SERVICE
3.BASIC SETUP
4.DETAILED SETUP
5.REVIEW
MENUS
1.TEST DEVICE
2.Loop Test
3.D/A Trim
1.DEVICE
INFORMATION
2.LCD DISPLAY
3.VOLUME
GEOMETRY *
4.SIGNAL
CONDITION
5.OUTPUT
CONDITION
6.THRESHOLD
SETTING
Online Menu
1.Status Group 1
2.Status Group 2
3.Status Group 3
4.Status Group 4
5.Status Group 5
6.Status Group 6
7.Status Group 15
8.Status Group 16
9.Status Group 17
— Status Group 18
— Status Group 19
1.VARIABLE MAPPING
2.Level
3.PV % rnge
4.A01
5. Dist
6.Vol *
7.Int. Temp
8.Temp *
9.RTD *
— St Vol *
— Loop Vlt
— SNR
— Targ Str
1. Tag
2.TRANSMITTER UNITS
3.RERANGING
4.Gauge Ht
5.RTD Usage *
6.EmpTank
1.Lev Units
2.Vol Units *
3.Tmp Units
1.Apply Values
2.Range Values
3.PV % Range
1.Universal Rev
2.Fld Dev Rev.
3.Software Rev.
1.Flange Type
2.Matrl
3.Meter
4.Antenna
5.Barrier
1.Variable Re-map
2.PV is
3.SV is
4.TV is
4 4V is
1.Threshold Units
2.Threshold Range
3.Threshold Snapshot
Do not go into “Threshold Setting” unless
specifically directed to do so by a Rosemount
Service Representative.
NOTE
Indicates whether error
messages are active. Refer to
“Alarm and Diagnostic
Messages” on page 5-3 for
assistance.
1.LINE 1
2.LINE 2
3.LANGUAGE
1.Current
2.PctRange
3.Level
4.Distance
5.Volume *
6.Int Temp
7.Temp *
8.RTD Ohms *
9.Std Volume *
— Loop Vlt
— SNR
— TargStr
1.TnkTyp
2.Diametr
3.LthOrHt
4.STRAPPING TABLE
(see note)
5.VOLUME COEFFIC
1.ANALOG OUTPUT
2.HART OUTPUT
1. K0
2. K1
3. K2
4. K3
5. K4
6.Std Temp
1.Entries Used
2.Max Entries
3.Lvl0
4.Vol0
5.Lvl1
6.Vol1
7.Lvl2
8.Vol2
9.Lvl3
— Vol3
— Lvl4
— Vol4
—Lvl9
— Vol9
1.PV LRV
2.PV URV
3.PV % rnge
4.PV Damp
5.UprNlZ
6.LowNlZ
1.PV AO
2.PV AO ALRM TYP
3.Loop test
4.D/A trim
5.Scaled D/A trim
1.Poll addr
2.Num req preams
3.Burst mode
4.Burst option
To enable volume calculations based on
a strapping table, the “strap table” option
must be selected for tank type.
1.Strap table
2.Ver Cylinder
3.Hor Cylinder
4.Ver Bullet
5.Hor Bullet
6.Sphere
7.None
— English
— German
— French
— Spanish
1.Current
2.Pct Rng
3. PV
NOTE:
* Selections in italics
are not available with the APEX
Sentry Radar Gauge