EasyManuals Logo
Home>Emerson>Measuring Instruments>Rosemount Apex

Emerson Rosemount Apex User Manual

Emerson Rosemount Apex
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
Reference Manual
00809-0100-4731, Rev FA
April 2003
A-7
APEX
and APEX Sentry
Radar Gauge
Power Supply APEX and APEX Sentry
90 to 250 V ac ±10%, 50/60 Hz
or
18 to 36 V dc
Power Consumption
< 8 watts
Input APEX only (Non-intrinsically safe output)
Accepts one RTD signal (optional), as defined in the following table:
APEX Sentry (and APEX with intrinsically safe output option code 2)
No RTD input available
Output APEX and APEX Sentry
4-20 mA analog signal (10.5 to 55.0 V dc powered), superimposed with a
digital HART signal
APEX output can be configured to provide level, volume, or standard
volume
Default analog saturation settings: minimum is 3.9 mA; maximum is 20.8
mA
Available with optional intrinsically safe 4–20 mA output for use with
galvanically isolated barriers
CALIBRATION APEX and APEX Sentry
Continuous frequency self-calibration ensures stated level accuracy
SOFTWARE
FUNCTIONALITY
APEX and APEX Sentry
Gauges are capable of digital communication over the 4–20 mA output
loop without disruption using the HART Communications Protocol.
All configuration data and programs are retained in non-volatile memory.
Upon power interruption, all data is available when power is restored.
WEIGHT APEX and APEX Sentry
Less than 19 lb (9 kg) with an ASME B.16 (ANSI) 2-in. Class 150 (DN 50,
PN 16) flange
Less than 23 lb (10 kg) with an ASME B.16 (ANSI) 3-in. Class 150 (DN 80,
PN 16) flange
Less than 30 lb (14 kg) with an ASME B.16 (ANSI) 4-in. Class 150 (DN
100, PN 16) flange
Input Range Accuracy
Pt 100 3-
or 4-wire RTD
–40 to 400 °F
(–40 to 204 °C)
±1.8°F
(
±1 °C)

Table of Contents