EasyManuals Logo

Emerson Rosemount Xstream Series Instruction Manual Addendum

Emerson Rosemount Xstream Series
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #98 background imageLoading...
Page #98 background image
Emerson Process Management GmbH & Co. OHG4-6
X-STREAM XEFD
Instruction Manual
HASXEDE-IM-EX
03/2012
4.2 Replacement of Parts
EXPLOSION HAZARD BY REPLACEMENTS PARTS
Replacement of parts found defective is permitted only by using original
parts!
Violation voids the approvals and may cause explosions!
4.2 Replacement of Parts
Specically for ATEX approved analyzers
Cable glands
NOT FOR analyzers for
vapor recovery applications!
Any ATEX approved ameproof type without
compound, suitable according EN 60079-14,
e. g.
- 8163/2 A2F M20 by Stahl
Cable glands
suitable for all ATEX
approved variations
Any ATEX approved ameproof type with
compound, suitable according EN 60079-14,
e. g.
- ADE 1FC ISO 20 No. 05 by CAPRI, or
- 8163/2–PXSS2K M20 by Stahl
Cable entries stopping plugs
Any ATEX approved ameproof type, e. g.
- 120209 by CAPRI
Male thread: M20 x 1,5
Spare part # ETC01754
Parts beside the cast enclosure, the safety of the X-STREAM XEFD relies on:

Table of Contents

Other manuals for Emerson Rosemount Xstream Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Rosemount Xstream Series and is the answer not in the manual?

Emerson Rosemount Xstream Series Specifications

General IconGeneral
BrandEmerson
ModelRosemount Xstream Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals