EasyManuals Logo

Enclustra Mercury XU5 User Manual

Enclustra Mercury XU5
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
Warning!
Other flash memory devices may be equipped in future revisions of the Mercury XU5 SoC module.
Please check the user manual regularly for updates.
2.18.2 Signal Description
The eMMC flash signals are connected to the MIO pins 13-22 for 8-bit data transfer mode. The command
signal has a 4.7 k pull-up resistor to 1.8 V and the data lines have 47 k pull-up resistors to 1.8 V.
2.19 SD Card
An SD card can be connected to the PS MIO pins 45-51. The corresponding MIO pins are available on the
module connector. Information on SD card boot mode is available in Section 3.8.
Please note that external pull-ups are needed for SD card operation. Depending on the selected voltage for
VCC_CFG_MIO, a level shifter to 3.3 V may be required (some level shifters also have built-in pull-ups).
For booting from an Ultra High Speed (UHS) SD card, an SD 3.0 compliant level shifter is required on the
base board and VCC_CFG_MIO must be set to 1.8 V. Please note that this boot mode has not been tested,
but it may be supported in the future.
2.20 Gigabit Ethernet (PS)
Two 10/100/1000 Mbit Ethernet PHYs are available on the Mercury XU5 SoC module, one connected to the
PS via RGMII interface, and one connected to PL via RGMII.
2.20.1 Ethernet PHY Type
Table 29 describes the equipped Ethernet PHY (PS) device type on the Mercury XU5 SoC module.
PHY Type Manufacturer Type
KSZ9031RNX Microchip (Micrel) 10/100/1000 Mbit
Table 29: Gigabit Ethernet PHY (PS) Type
2.20.2 Signal Description
Ethernet PHY 0 is connected to ETH 0 controller from the PS I/O bank 501. One of the Ethernet TX data
signals is shared with the PCIe reset signal (PERST#); if the application requires a hard PCIe block, the ETH
0 interface is not available. Refer to Section 2.9.2 for details on the PERST# connection.
Warning!
Gigabit Ethernet 0 interface is not available when the PCIe endpoint in the PS is used (because of the
PERST# connection).
The interrupt output of the Ethernet PHY is connected to the I2C interrupt line, available on MIO12 pin.
D-0000-445-001 43 / 64 Version 07, 25.07.2019

Table of Contents

Other manuals for Enclustra Mercury XU5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enclustra Mercury XU5 and is the answer not in the manual?

Enclustra Mercury XU5 Specifications

General IconGeneral
BrandEnclustra
ModelMercury XU5
CategoryControl Unit
LanguageEnglish

Related product manuals