5.2 Recommended Operating Conditions
Table 48 indicates the recommended operating conditions for Mercury XU5 SoC module. The values given
are for reference only; for details please refer to the Zynq UltraScale+ MPSoC, DC and AC Switching Char-
acteristics Datasheet [21].
Symbol Description Rating Unit
VCC_MOD Supply voltage relative to GND 4.75 to 15.75 V
VCC_BAT Supply voltage for MPSoC battery-backed RAM and battery-
backed RTC
2.7 to 3.6 V
VCC_IO_[x]
Output drivers supply voltage relative to GND
Refer to
V
VCC_CFG_[x] Section 2.9.5
V_IO I/O input voltage relative to GND -0.2 to V
CCO
+0.2 V
Temperature
Temperature range for extended temperature modules (E)
*
0 to +85
C
Temperature range for industrial modules (I)
*
-40 to +85
C
Table 48: Recommended Operating Conditions
Warning!
*
The components used on the hardware are specified for the relevant temperature range. The user
must provide adequate cooling in order to keep the temperature of the components within the specified
range.