Trouble-shooting Cerabar S/Deltabar S
158 Endress+Hauser
Explanation XD_ERROR and BLOCK_ERROR
Error type Code XD_ERROR
Value
XD_ERROR Text BLOCK_
ERROR
Value
BLOCK_ERROR Text PV Status
Alarm 747 17 General Error 0 Other Bad Sensor Failure
707, 711, 713, 721,
722, 723, 741
18 Calibration Error 8 Output Failure Uncertain Config Error
719, 750 19 Configuration Error 8 Output Failure Uncertain Config Error
101, 122, 703, 704,
705, 716, 725, 737,
738, 739, 742, 743,
744, 746, 748
20 Electronics Failure 5 Device Fault State Set Bad Device Failure
113, 728, 729, 736 20 Electronics Failure 9 Memory Failure Bad Device Failure
110, 121, 130, 131,
132, 133, 135
23 Data Integrity Error 11 Lost NV Data Bad Device Failure
Error 115, 120, 715, 717,
718, 720
17 General Error 0 Other – Alarm: Bad Non Specific
– Warning: Status Uncertain
730, 731, 732, 733 19 Configuration Error 8 Output Failure – Alarm: Bad Non Specific
– Warning: Status Uncertain
122, 727, 726, 740 20 Electronics Failure 5 Device Fault State – Alarm: Bad Non Specific
– Warning: Status Uncertain
Warning 106, 116, 134, 745 17 General Error 0 Other Uncertain Config Error
613 17 General Error 3 Simulate Active Uncertain Sim
702 17General Error11Lost NV Data Status Uncertain
710 18 Calibration Error 8 Output Failure Status Uncertain
602, 604 19 Configuration Error 8 Output Failure Uncertain Config Error
746 20 Electronics Failure 5 Device Fault State Set Status Uncertain
102, 700, 706 23 Data Integrity Error 11 Lost NV Data Status Uncertain