What to do if the Endress+Hauser Gammapilot FMG50 firmware is incompatible?
- MMiguel OconnorSep 5, 2025
Check software. Flash or change main electronic module.
What to do if the Endress+Hauser Gammapilot FMG50 firmware is incompatible?
Check software. Flash or change main electronic module.
What to do if the Endress+Hauser Measuring Instruments module is incompatible?
Check if correct electronic module is plugged. Replace electronic module.
What to do if the Endress+Hauser Measuring Instruments main electronics are defective?
Replace main electronics.
What to do if the Endress+Hauser Gammapilot FMG50 main electronics are faulty?
Restart device. Contact service.
What to do if the Endress+Hauser Gammapilot FMG50 Measuring Instruments memory content is inconsistent?
Transfer data or reset device. Contact service.
What to do if the Endress+Hauser Gammapilot FMG50 Measuring Instruments current output is out of range?
Check process. Check current output settings.
Measuring Principle | Gamma radiation |
---|---|
Housing Material | Aluminum or Stainless steel |
Application | Level measurement in liquids and bulk solids |
Process Temperature | -40 to +80 °C |
Process Pressure | Up to 40 bar |
Output Signal | 4-20 mA, HART |
Protection Class | IP66 |
Communication | HART |
Certificates/Approvals | ATEX, IECEx |
Ambient Temperature | -40 to +60 °C (-40 to +140 °F) |
Explains the purpose and scope of the operating instructions.
Explains safety and information symbols used throughout the manual.
Details personnel qualifications and intended applications.
Emphasizes trained specialists and safe operation practices.
Covers radiation safety guidelines, shielding, time, and distance.
Explains CE and EAC conformity marks.
Details the physical design and lists main components of the FMG50.
Explains device nameplate information and lists accompanying documents.
Covers checks upon receipt, identification methods, and storage.
Discusses general mounting principles and optional features.
Details mounting for Level, Density, Interface, and Concentration measurements.
Lists essential checks after the device has been installed.
Covers compartment, HART, terminals, cables, protection, and connectors.
Details connection options for the RIA15.
Provides wiring steps and examples for various applications.
Lists checks after wiring and mentions SIL application requirements.
Lists HART protocol, FieldCare/DeviceCare, RIA15, and WirelessHART operation.
Covers local, service interface, RIA15, Bluetooth, and SmartBlue App operations.
Explains software and hardware methods for locking configuration.
Details the process and types of device resets.
Stresses post-installation and post-connection checks before commissioning.
Guides through device identification, measurement settings, and calibration.
Explains background, point level, and full calibration processes.
Details density compensation using RSG45.
Details error signals, types, and calibration errors.
Troubleshoots issues with the SmartBlue app.
Explains event display and lists diagnostic events with remedies.
Covers principles, reaction, limits, settings, and parameters for gammagraphy.
Explains clock function and setting the real-time clock.
Covers exterior cleaning, repair process, and Ex-certified device repairs.
Discusses replacement procedures, calibration, and HistoROM usage.
Covers ordering parts, device return, disposal, and contact info.
Lists Commubox and Field Xpert devices.
Covers retaining brackets, clamps, and pole mounts with dimensions.
Lists various FHG51 clamping device models for density measurement.
Details the RIA15 and its required HART communication resistor.
Refers to the "Technical Information FMG50" document.
Lists various technical information and accessory documents available.
Covers Functional Safety (SIL), Heartbeat, and Ex approval details.
Lists other standards, certificate access, CE, EAC, and Overfill prevention.