Levelflex FMP51, FMP52, FMP54 Operating options
Endress+Hauser 67
1
2
5
4
3
(B)
(A)
CDI
Sparepart:FMP52X-AB
WP SIM
SW
exworks
SWupdate#1
SWupdate#2
02.01.03Dev_R
DISPL
A0013132
1. Unscrew the lid from the compartment for the display and operating module.
2. Slightly turn the display and operating module to remove it from the compartment.
3. Set the locking switch (WP: Write Protection) into the desired position. (A): unlocked; (B):
locked.
4. Attach the display and operating module in the desired orientation until it closes with a snap.
5. Screw the lid onto the compartment.
Locking the menu via parameter settings (software locking)
Step Parameter Action Description
1
Setup ® Advanced setup
® Define access code
To lock the device:
Enter a user-defined access code.
(® ä 126)
2
Setup ® Advanced setup
® Enter access code
To unlock the device:
Enter the previously defined access code.
(® ä 125)
3
Setup ® Advanced setup
® Enter access code
To lock the device again:
Enter a number other than the previously defined access code.
(® ä 125)