Electrical connection Micropilot FMR60B PROFINET with Ethernet-APL
28 Endress+Hauser
Dual compartment housing, L-form
+
-
1
2
3
A0045842
 6 Connection terminals and ground terminal in the connection compartment
1 Positive terminal
2 Negative terminal
3 Internal ground terminal
6.2.6 Cable entries
11 11
2
A
B D E
2 2 2
C
1
2
A0046584
A Single compartment housing, plastic
B Single compartment housing, aluminum
C Single compartment housing, 316L hygiene
D Dual compartment housing
E Dual compartment housing, L-form
1 Cable entry
2 Dummy plug
The type of cable entry depends on the device version ordered.
Always route connecting cables downwards so that moisture cannot penetrate the
connection compartment.
If necessary, create a drip loop or use a weather protection cover.
6.2.7 Available device plugs
In the case of devices with a plug, it is not necessary to open the housing for
connection purposes.
Use the enclosed seals to prevent the penetration of moisture into the device.