EasyManua.ls Logo

Endress+Hauser Micropilot FMR60B - Ensuring the degree of protection; Post-connection check

Endress+Hauser Micropilot FMR60B
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR60B PROFINET with Ethernet-APL Electrical connection
Endress+Hauser 29
Devices with M12 plug
2
1
3
4
A0011175
 7 View of the plug-in connection on the device
1 APL signal -
2 APL signal +
3 Shielding
4 Not assigned
Various M12 sockets are available as accessories for devices with M12 plugs.
6.3 Ensuring the degree of protection
6.3.1 Cable entries
M20 coupling, plastic, IP66/68 NEMA TYPE 4X/6P
M20 coupling, nickel-plated brass, IP66/68 NEMA TYPE 4X/6P
M20 coupling, 316L, IP66/68 NEMA TYPE 4X/6P
M20 thread, IP66/68 NEMA Type 4X/6P
G1/2 thread, IP66/68 NEMA Type 4X/6P
If the G1/2 thread is selected, the device is delivered with an M20 thread as standard
and a G1/2 adapter is included with the delivery, along with the corresponding
documentation
NPT 1/2 thread, IP66/68 NEMA Type 4X/6P
Dummy plug transport protection: IP22, NEMA TYPE 2
M12 plug
When housing is closed and connecting cable is plugged in: IP66/67, NEMA Type 4X
When housing is open or connecting cable is not plugged in: IP20, NEMA Type 1
NOTICE
M12 plug: Loss of IP protection class due to incorrect installation!
The degree of protection only applies if the connecting cable used is plugged in and
screwed tight.
The degree of protection only applies if the connecting cable used is specified according
to IP67, NEMA Type 4X.
The IP protection classes are only maintained if the dummy cap is used or the cable is
connected.
6.4 Post-connection check
 Are the device or cables undamaged (visual inspection)?
 Do the cables used comply with the requirements?
 Do the mounted cables have strain relief?
 Cable glands mounted, securely tightened and leak-tight?
 Does the supply voltage correspond to the specifications on the nameplate?
 No reverse polarity, terminal assignment correct?
 Cover screwed down correctly?
 Cover lock tightened correctly?