EasyManua.ls Logo

Endress+Hauser Micropilot FMR60B - Page 56

Endress+Hauser Micropilot FMR60B
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostics and troubleshooting Micropilot FMR60B PROFINET with Ethernet-APL
56 Endress+Hauser
Diagnostic
number
Short text Remedy instructions Status
signal
[from the
factory]
Diagnostic
behavior
[from the
factory]
168 Build-up detected Check process conditions M Warning
1)
Diagnostic of electronic
232 Real time clock
defective
Replace main electronics M Warning
242 Firmware incompatible 1. Check software
2. Flash or change main electronic
module
F Alarm
252 Module incompatible 1. Check if correct electronic
module is plugged
2. Replace electronic module
F Alarm
270 Main electronics
defective
Replace main electronics F Alarm
272 Main electronics faulty 1. Restart device
2. Contact service
F Alarm
273 Main electronics
defective
Replace main electronics F Alarm
282 Data storage
inconsistent
Restart device F Alarm
283 Memory content
inconsistent
1. Restart device
2. Contact service
F Alarm
287 Memory content
inconsistent
1. Restart device
2. Contact service
M Warning
331 Firmware update failed 1. Update firmware of device
2. Restart device
M Warning
388 Electronics and
HistoROM defective
1. Restart device
2. Replace electronics and
HistoROM
3. Contact service
F Alarm
Diagnostic of configuration
410 Data transfer failed 1. Retry data transfer
2. Check connection
F Alarm
412 Processing download Download active, please wait C Warning
435 Linearization faulty Check linearization table F Alarm
436 Date/time incorrect Check date and time settings. M Warning
1)
437 Configuration
incompatible
1. Update firmware
2. Execute factory reset
F Alarm
438 Dataset different 1. Check dataset file
2. Check device parameterization
3. Download new device
parameterization
M Warning
484 Failure mode
simulation active
Deactivate simulation C Alarm
485 Process variable
simulation active
Deactivate simulation C Warning
495 Diagnostic event
simulation active
Deactivate simulation S Warning
538 Configuration Sensor
Unit invalid
1. Check sensor configuration
2. Check device configuration
F Alarm
585 Simulation distance Deactivate simulation C Warning