Technical data Micropilot FMR60B PROFINET with Ethernet-APL
74 Endress+Hauser
Integrated antenna, PEEK, 40 mm (1.5 in) in buffer vessel
Media group Measuring range
A0
r
1.2 to 1.4) 1.5 m (5 ft)
A
r
1.4 to 1.9) 3 m (10 ft)
B
r
1.9 to 4) 6 m (20 ft)
C
r
4 to 10) 13 m (43 ft)
D
r
>10) 20 m (66 ft)
Encapsulated antenna, PVDF, 40 mm (1.5 in) in buffer vessel
Media group Measuring range
A0
r
1.2 to 1.4) 4 m (13 ft)
A
r
1.4 to 1.9) 7.5 m (24.6 ft)
B
r
1.9 to 4) 15 m (49.2 ft)
C
r
4 to 10) 25 m (82 ft)
D
r
>10) 35 m (114.8 ft)
PTFE Drip-off antenna, 50 mm (2 in) in buffer vessel
Media group Measuring range
A0
r
1.2 to 1.4) 4 m (13 ft)
A
r
1.4 to 1.9) 7 m (23 ft)
B
r
1.9 to 4) 13 m (43 ft)
C
r
4 to 10) 28 m (92 ft)
D
r
>10) 44 m (144 ft)
Measurement in vessel with agitator
Vessel with agitator - measuring conditions
Turbulent medium surface (e.g. from filling from above, stirrers and baffles)