Technical data Micropilot FMR60B PROFINET with Ethernet-APL
92 Endress+Hauser
Integrated antenna, PEEK, 40 mm (1.5 in)
Process connection thread 1-½"
Seal T
p
Process pressure range
A0047833
FKM Viton GLT –40 to +150 °C (–40 to +302 °F) –1 to 20 bar (–14.5 to 290 psi)
FKM Viton GLT –40 to +200 °C (–40 to +392 °F) –1 to 20 bar (–14.5 to 290 psi)
FFKM Kalrez –20 to +150 °C (–4 to +302 °F) –1 to 20 bar (–14.5 to 290 psi)
FFKM Kalrez –20 to +200 °C (–4 to +392 °F) –1 to 20 bar (–14.5 to 290 psi)
The pressure range may be further restricted in the event of a CRN approval.
Dielectric constant For liquids
ε
r
≥  1.2
Contact Endress+Hauser for applications with lower dielectric constants than indicated.