10.7 PROFIBUS-PA parameters
Parameter Matrix
VH
Index
(Slot = 1)
Data type Read Write Data
length
Composite List Directory - 1 Octet String yes 24
DEVICE_ID V99H0 25 Octet String yes 16
Actual Error 90 52 Unsigned 16 yes 2
Device Bus Address 94 57 Integer 8 yes 1
Main measured value 00 108 Float yes 4
Temp. measured value 01 109 Float yes 4
Ext. binary input 05 110 Unsigned 8 yes 1
Operating mode 06 111 Unsigned 8 yes 1
Measuring cell 07 112 Unsigned 8 yes 1
Input damping 10 113 Unsigned 8 yes yes 1
Set ATC/MTC 11 114 Unsigned 8 yes yes 1
MTC temperature 13 115 Float yes yes 4
Cell constant 22 116 Float yes 4
Adaptation factor 24 117 Float yes yes 4
Temp. offset 28 118 Float yes 4
Select substance MR 1 60 119 Unsigned 8 yes yes 1
Select substance MR 2 61 120 Unsigned 8 yes yes 1
Select substance MR 3 62 121 Unsigned 8 yes yes 1
Select substance MR 4 63 122 Unsigned 8 yes yes 1
Instrument number 91 123 Unsigned 32 yes 4
Software version 92 124 Unsigned 16 yes 2
Reset counter 95 125 Unsigned 8 yes 1
SAP code 96 126 Octet String yes 18
Measuring point
description
A0 127 Octet String yes yes 32
PNO ID number A1 128 Unsigned 16 yes 2
PROFIBUS
®
interface Mycom CLM 152
68 Endress+Hauser

Table of Contents

Other manuals for Endress+Hauser Mycom CLM 152

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Mycom CLM 152 and is the answer not in the manual?

Endress+Hauser Mycom CLM 152 Specifications

General IconGeneral
BrandEndress+Hauser
ModelMycom CLM 152
CategoryTransmitter
LanguageEnglish

Related product manuals