Proline Promass F 500 Modbus RS485 Commissioning
Endress+Hauser 103
Assign current output 1 to n
→ 103
Current span
→ 103
0/4 mA value
→ 104
20 mA value
→ 104
Fixed current
→ 104
Failure mode
→ 104
Failure current
→ 104
Parameter overview with brief description
Parameter Prerequisite Description Selection / User
interface / User
entry
Factory setting
Assign current output 1 to n – Select process variable for
current output.
• Off
• Mass flow
• Volume flow
• Corrected volume
flow
• Target mass flow
*
• Carrier mass flow
*
• Density
• Reference density
• Concentration
*
• Temperature
• Carrier pipe
temperature
*
• Electronic
temperature
• Oscillation
frequency 0
• Oscillation
amplitude 0
*
• Frequency
fluctuation 0
• Oscillation
damping 0
• Oscillation
damping
fluctuation 0
• Signal asymmetry
• Exciter current 0
Mass flow
Terminal number – Shows the terminal numbers
used by the current output
module.
• Not used
• 24-25 (I/O 2)
• 22-23 (I/O 3)
• 20-21 (I/O 4)
*
–
Current span – Select current range for
process value output and
upper/lower level for alarm
signal.
• 4...20 mA NAMUR
• 4...20 mA US
• 4...20 mA
• 0...20 mA
• Fixed current
Country-specific:
• 4...20 mA NAMUR
• 4...20 mA US
Signal mode – Select the signal mode for the
current output.
• Passive
• Active
Passive