EasyManua.ls Logo

Endress+Hauser Proline Prowirl 73 - Post-Installation Check

Endress+Hauser Proline Prowirl 73
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation Proline Prowirl 73
24 Endress+Hauser
3.3.4 Mounting the transmitter (remote)
The transmitter can be mounted in the following ways:
Wall mounting
Pipe mounting (with separate mounting kit, accessories ä 59)
The transmitter and the sensor must be mounted separate in the following circumstances:
poor accessibility,
lack of space,
extreme ambient temperatures.
"
Caution!
Danger of electronics overheating!
If the device is mounted to warm piping, make certain that the housing temperature does not
exceed the max. permissible temperature value.
Standard: –40 to +80 °C (–40 to +176 °F)
EEx-d/XP version: –40 to +60 °C (–40 to +140 °F)
ATEX II 1/2 GD version/dust ignition-proof: –20 to +55 °C (–4 to +131 °F)
Mount the transmitter as illustrated in the diagram.
A0003801
Fig. 13: Mounting the transmitter (remote version)
A Direct wall mounting
BPipe mounting
* Dimensions for version without local operation
3.4 Post-installation check
Perform the following checks after installing the measuring device in the piping:
ANSCHLUSSKLEMMEN - FIELD TERMINALS
ANSCHLUSSKLEMMEN - FIELD TERMINALS
A
B
220 / *214
215/ *209
(8.66 / *8.43)
(8.46 / *8.23)
mm (inch)
Ø 2070
0.792.75)
Device condition and specifications Notes
Is the device damaged (visual inspection)? -
Do the process temperature/pressure, ambient temperature, measuring range, etc.
correspond to the specifications of the device?
ä 78
Installation Notes
Does the arrow on the pipe or on the sensor match the direction of flow through
the pipe?
-
Are the measuring point number and labeling correct (visual inspection)? -
Is the orientation chosen for the sensor correct, in other words suitable for sensor
type, fluid properties (outgassing, with entrained solids) and fluid temperature?
ä 17
Process environment/process conditions Notes
Is the measuring device protected against moisture and direct sunlight? -