Proline Prowirl 73 Technical data
Endress+Hauser 85
10.1.9 Operating conditions: process
Medium temperature range
DSC sensor (differential switched capacitor; capacitive sensor)
DSC standard sensor –200 to +400 °C (–328 to +752 °F)
DSC sensor Inconel –200 to +400 °C (–328 to +752 °F)
Seals
Graphite –200 to +400 °C (–328 to +752 °F)
Viton –15 to +175 °C (+5 to +347 °F)
Kalrez –20 to +275 °C (–4 to +527 °F)
Gylon (PTFE) –200 to +260 °C (–328 to +500 °F)
Sensor
Stainless steel –200 to +400 °C (–328 to +752 °F)
Special version for high fluid temperatures
(on request)
–200 to +450 °C (–328 to +842 °F)
–200 to +440 °C (–328 to +824 °F), Ex version