Proline Prowirl 73 Technical data
Endress+Hauser 93
10.2 Dimensions of flow conditioner
Dimensions according to:
EN 1092-1 (DIN 2501)
ANSI B16.5
JIS B2220
Material 1.4404 (316/316L), in compliance with NACE MR0175-2003 and MR0103-2003
A0001941
D1: The flow conditioner is fitted at the outer diameter between the bolts.
D2: The flow conditioner is fitted at the indentations between the bolts.
Dimensions of flow conditioner according to EN (DIN)
s
D2
D1
DN Pressure rating
Centering diameter
[mm]
D1 / D2 *
s
[mm]
Weight
[kg]
15
PN 10 to 40
PN 63
54.3
64.3
D2
D1
2.0
0.04
0.05
25
PN 10 to 40
PN 63
74.3
85.3
D1
D1
3.5
0.12
0.15
40 PN 10 to 40
PN 63
95.3
106.3
D1
D1
5.3
0.3
0.4
50 PN 10 to 40
PN 63
110.0
116.3
D2
D1
6.8
0.5
0.6
80 PN 10 to 40
PN 63
145.3
151.3
D2
D1
10.1 1.4
100 PN 10/16
PN 25/40
PN 63
165.3
171.3
176.5
D2
D1
D2
13.3 2.4
150 PN 10/16
PN 25/40
PN 63
221.0
227.0
252.0
D2
D2
D1
20.0
6.3
7.8
7.8
200 PN 10
PN 16
PN 25
PN 40
274.0
274.0
280.0
294.0
D1
D2
D1
D2
26.3
11.5
12.3
12.3
15.9
250 PN 10/16
PN 25
PN 40
330.0
340.0
355.0
D2
D1
D2
33.0
25.7
25.7
27.5
300 PN 10/16
PN 25
PN 40
380.0
404.0
420.0
D2
D1
D1
39
.6
36.4
36.4
44.7
* D1 The flow conditioner is fitted at the external diameter between the bolts.
D2 The flow conditioner is fitted at the indentations between the bolts.